- 8B PDO config: ULINT-sized payload, no 0x1A01 diag PDO on SM3 (device rejected SM3=8 with diag assigned: 'size not allowed, min/max 0xa') - twin_layout_blob_sized(): single 64-bit mapping entry for 8B payloads - Ticker: per-byte XOR 0x5A transform in 8B mode so TwinCAT can verify every byte individually (1KB path unchanged, const-guarded) - TwinCAT automation scripts: deploy with RPC retry, LinkVariables-based whole-array relink (element links only carry 1 byte), ADS watch, diag - Docs: 8B design, verification methodology, test report
19 lines
928 B
PowerShell
19 lines
928 B
PowerShell
#Requires -RunAsAdministrator
|
|
$ErrorActionPreference = 'Continue'
|
|
# Open project in visible XAE and leave it running for interactive inspection.
|
|
$dte = New-Object -ComObject TcXaeShell.DTE.17.0
|
|
$dte.MainWindow.Visible = $true
|
|
try { $dte.SuppressUI = $false } catch {}
|
|
$dte.Solution.Open('C:\Users\tonycao\work\twincat3-auto-cli\TwinCAT_EL6695_Primary\TwinCATProject1.sln')
|
|
Start-Sleep 25
|
|
$sm = $null
|
|
for ($i = 0; $i -lt 20; $i++) {
|
|
try { $sm = $dte.Solution.Projects.Item(1).Object; if ($sm) { break } } catch {}
|
|
Start-Sleep 3
|
|
}
|
|
if (-not $sm) { Write-Host 'no sysmgr'; exit 1 }
|
|
try { $sm.SetTargetNetId('169.254.176.217.1.1'); Write-Host 'target set' } catch { Write-Host "target: $_" }
|
|
Start-Sleep 3
|
|
try { Write-Host "IsTwinCATStarted=$($sm.IsTwinCATStarted)" } catch {}
|
|
Write-Host 'XAE left open. Inspect: TIID -> 设备 1 (EtherCAT) -> 模块 3 (EK1100) -> 模块 10 (EL6695) -> IO Inputs / IO Outputs -> Online tab'
|